QQ1456921957 MSN wklt1121@msn.com
Pump Speed Drive > CHES > CHES-Single Unit

CHES-Single Unit

Structure:

Size:

Specification:

机   型
马达出力P1(w)
定额水量m³/h
定额扬程(m)
建议恒压设定值kg/cm²
吸入口径inch
出水口径inch
尺          寸(mm)
L
W
H
H1
H2
CHES 2-30
670
3
30
0.5-3.5
1
1
356
200
450
90
215
CHES 2-40
860
3
40
0.5-4.5
1
1
414
200
450
90
215
CHES 2-50
1000
3
50
0.5-5.5
1
1
432
200
450
90
215
CHES 2-60
1200
3
60
0.5-6.5
1
1
450
200
450
90
215
CHES 4-20
810
6
20
0.5-2.5
1-1/4
1
348
200
450
90
215
CHES 4-30
1260
6
30
0.5-3.5
1-1/4
1
416
200
450
90
215
CHES 4-40
1500
6
40
0.5-4.5
1-1/4
1
444
200
450
90
215
CHES 8-20
1160
9
20
0.5-2.5
1-1/2
1-1/2
345
220
560
110
280
CHES 8-25
1350
9
28
0.5-3.2
1-1/2
1-1/2
415
220
560
110
280
CHES 8-30
1830
9
35
0.5-4.0
1-1/2
1-1/2
415
220
560
110
280
CHES 8-40
2260
9
40
0.5-4.5
1-1/2
1-1/2
450
220
560
110
280
CHES 12-20
880
12
25
0.5-3.0
1-1/2
1-1/2
385
220
560
110
280
CHES 12-30
1000
12
38
0.5-4.2
1-1/2
1-1/2
463
220
560
110
280
CHES 12-40
1720
12
50
0.5-5.5
1-1/2
1-1/2
463
220
560
110
280

Performances:

Function:

The controller senses the pressure change in the water supply piping through the signals detected by pressure transmitter,and compares with the preset pressure;then the controller will send continous signals(DC0~10V) to inverter, for adjusting its frequency (0~60HZ) accordingly.the pump speed varies according to the frequency converted thus maintaining the set pressure.

Adjustable Pressure:

ADJUSTABLE PRESSURE
A wide range of pressure settings is available through the use of the luck control system .the desired pressure is easily established by means of a “set screw”(a full 25 turns possible);
MATOR NOT IN USE MATOR STOP MODE
When the water top is turned off,the indicator light is green,showing the controller is in the “motor stop”mode.the smooth transition to the”Stop Mode”is accomplished as the controller reduces the motor speed 10% in the first 20 seconds and then, in the next 15 seconds. The motor power is gradually reduced to zero.
WATER IN USE
When water use is initiated ,the controller will start the motor at 85% of the pre –set pressure in order of boost/maintain the desired pressure.
LEAKAGE DETECTION
The controller continuously monitors the incoming water pressure and ,if pressure is under 85% of the pre-set level (due to leaks),if will start the pump to compensate for the pressure drop.
NO WATER AND LOST PRESSURE PROTECTION
When the motor is at full speed and cannot achieve at least 20% of the pre-set pressure,then there is either (a) no incoming water supply or (b) the impller has failed.the red indicator light illum inates and ,after 20 seconds ,the motor will auto matically stop. The source of the problem must be determined; turn off the electricity for 15 seconds and restart.
CONSTANT PRESSURE
Regardless of the incoming water supply pressure the controller will assure the pre-set pressure is never exceeded.
THREE COLOR INDICATORS
Orange(normal)green(stop)red(run dry)
DESIGNED PATENTED INVERTER PROVIDES:
Low noise(52db),gentle start/stop of motor ,low starting current, elimination of“water hammer”and greatly reduced vibration.
The inverter causes the system to consume less energy than most other units.